smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.15.0-65-generic] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.9 Device Model: ST3250824AS Serial Number: 4NF002V0 Firmware Version: 3.AAH User Capacity: 250,058,268,160 bytes [250 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA/ATAPI-7 (minor revision not indicated) Local Time is: Tue Oct 15 16:09:12 2019 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 100) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 106 093 006 Pre-fail Always - 42118692 3 Spin_Up_Time 0x0003 087 085 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 097 097 020 Old_age Always - 3998 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 089 060 030 Pre-fail Always - 819980609 9 Power_On_Hours 0x0032 083 083 000 Old_age Always - 15137 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 097 097 020 Old_age Always - 3700 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 054 048 045 Old_age Always - 46 (Min/Max 27/47) 194 Temperature_Celsius 0x0022 046 052 000 Old_age Always - 46 (0 17 0 0 0) 195 Hardware_ECC_Recovered 0x001a 056 048 000 Old_age Always - 20823643 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 Data_Address_Mark_Errs 0x0032 100 253 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 156 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 156 occurred at disk power-on lifetime: 2311 hours (96 days + 7 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 10 51 01 2e 51 1c ed Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 37 00 01 2e 51 1c ed 00 00:10:20.286 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3] 27 00 00 2e 51 1c e0 00 00:10:18.206 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] 37 00 00 2e 51 1c ed 00 00:10:18.147 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3] 27 00 01 2e 51 1c e0 00 00:10:17.930 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] 37 00 01 2e 51 1c ed 00 00:10:17.871 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3] Error 155 occurred at disk power-on lifetime: 2311 hours (96 days + 7 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 10 51 01 2e 51 1c ed Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 37 00 01 2e 51 1c ed 00 00:10:15.818 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3] 27 00 00 2e 51 1c e0 00 00:10:18.206 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] 37 00 00 2e 51 1c ed 00 00:10:18.147 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3] 27 00 01 6f 59 1c e0 00 00:10:17.930 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] 29 00 01 6f 59 1c e0 00 00:10:17.871 READ MULTIPLE EXT Error 154 occurred at disk power-on lifetime: 2310 hours (96 days + 6 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 10 51 01 2e 51 1c ed Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 37 00 01 2e 51 1c ed 00 00:08:17.899 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3] 27 00 00 2e 51 1c e0 00 00:08:22.707 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] 37 00 00 2e 51 1c ed 00 00:08:22.647 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3] 27 00 01 2e 51 1c e0 00 00:08:22.431 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] 37 00 01 2e 51 1c ed 00 00:08:22.359 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3] Error 153 occurred at disk power-on lifetime: 2310 hours (96 days + 6 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 10 51 01 2e 51 1c ed Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 37 00 01 2e 51 1c ed 00 00:08:17.899 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3] 27 00 00 2e 51 1c e0 00 00:08:17.899 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] 37 00 00 2e 51 1c ed 00 00:08:17.899 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3] 27 00 01 6f 59 1c e0 00 00:08:17.899 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] 29 00 01 6f 59 1c e0 00 00:08:17.898 READ MULTIPLE EXT Error 152 occurred at disk power-on lifetime: 2244 hours (93 days + 12 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 10 51 01 2e 51 1c ed Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 37 00 01 2e 51 1c ed 00 00:26:55.366 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3] 27 00 00 2e 51 1c e0 00 00:26:55.249 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] 37 00 00 2e 51 1c ed 00 00:26:55.188 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3] 27 00 01 2e 51 1c e0 00 00:26:53.667 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] 37 00 01 2e 51 1c ed 00 00:26:53.505 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3] SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 15137 - # 2 Extended offline Completed without error 00% 15115 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.