------------------------- LIBDEBUG LOG ------------------------- [app] Application options: [app] locale: 1 [app] version: 0 [app] hide_tabs: 1 [app] scan: 1 [app] arg_add_virtual: [empty] [app] arg_add_device: [empty] [app] LibDebug options: [app] levels_enabled: 11111 [app] debug_colorize: false [app] {anonymous}::app_init_config(): Global config file: "gsmartcontrol.conf" [app] {anonymous}::app_init_config(): Local config file: "C:\Users\neo\AppData\Roaming\gsmartcontrol\gsmartcontrol.conf" [app] {anonymous}::app_init_config(): Old local config file: "C:\Users\neo\Documents\gsmartcontrol.conf" [rconfig] / [3] / config [4] /config default [4] /default [rconfig] Setting autosave config file to "C:\Users\neo\AppData\Roaming\gsmartcontrol\gsmartcontrol.conf" [rconfig] Starting config autosave with 180 sec. interval. [app] Current C locale: C [app] Current C++ locale: C [app] Current GTK theme: win32 [app] hz::data_file_find(): Data file "icon_hdd.png" found at ".". [app] hz::data_file_find(): Data file "icon_cddvd.png" found at ".". [app] get_smartctl_binary(): Smartmontools installation not found in "HKLM\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall\smartmontools\InstallLocation". [default] ENTER: "Cmdex::execute()" [app] Cmdex::execute(): Executing "'smartctl-nc.exe' -V". [default] EXIT: "Cmdex::execute()" [default] ENTER: "Cmdex::stopped_cleanup()" [default] ENTER: "Cmdex::unset_stop_timeouts()" [default] EXIT: "Cmdex::unset_stop_timeouts()" [default] EXIT: "Cmdex::stopped_cleanup()" [default] ENTER: "Cmdex::stopped_cleanup()" [app] StorageDetector::detect(): Starting drive detection. [app] Checking which drive corresponds to which \\.\PhysicalDriveN device... [app] Windows drive found: C. [app] Windows drive C is fixed. [app] Windows drive found: D. [app] Windows drive D is fixed. [app] Windows drive found: G. [app] Windows drive C corresponds to physical drive 0. [app] Windows drive D corresponds to physical drive 0. [app] Getting multi-port devices through smartctl --scan-open... [app] get_smartctl_binary(): Smartmontools installation not found in "HKLM\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall\smartmontools\InstallLocation". [default] ENTER: "Cmdex::execute()" [app] Cmdex::execute(): Executing "'smartctl-nc.exe' --scan-open". [default] EXIT: "Cmdex::execute()" [default] ENTER: "Cmdex::stopped_cleanup()" [default] ENTER: "Cmdex::unset_stop_timeouts()" [default] EXIT: "Cmdex::unset_stop_timeouts()" [default] EXIT: "Cmdex::stopped_cleanup()" [default] ENTER: "Cmdex::stopped_cleanup()" [app] get_smartctl_binary(): Smartmontools installation not found in "HKLM\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall\smartmontools\InstallLocation". [default] ENTER: "Cmdex::execute()" [app] Cmdex::execute(): Executing "'smartctl-nc.exe' -d ata --info --health --capabilities '/dev/csmi0,0'". [default] EXIT: "Cmdex::execute()" [default] ENTER: "Cmdex::stopped_cleanup()" [default] ENTER: "Cmdex::unset_stop_timeouts()" [default] EXIT: "Cmdex::unset_stop_timeouts()" [hz] Warning: exit: SMART status check returned "DISK FAILING" [hz] SMART status check returned "DISK OK" but some prefail Attributes are less than threshold. [default] EXIT: "Cmdex::stopped_cleanup()" [app] get_smartctl_binary(): Smartmontools installation not found in "HKLM\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall\smartmontools\InstallLocation". [default] ENTER: "Cmdex::execute()" [app] Cmdex::execute(): Executing "'smartctl-nc.exe' -d ata --info --health --capabilities '/dev/csmi0,2'". [default] EXIT: "Cmdex::execute()" [default] ENTER: "Cmdex::stopped_cleanup()" [default] ENTER: "Cmdex::unset_stop_timeouts()" [default] EXIT: "Cmdex::unset_stop_timeouts()" [hz] Warning: exit: Device open failed, or device did not return an IDENTIFY DEVICE structure. [default] EXIT: "Cmdex::stopped_cleanup()" [app] SmartctlParser::parse_full(): No ATA sections could be parsed. Returning. [app] Starting sequential scan of \\.\PhysicalDriveN devices... [app] Successfully opened "\\.\PhysicalDrive0". [app] Drive letters for: pd0: C:, D:. [app] get_smartctl_binary(): Smartmontools installation not found in "HKLM\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall\smartmontools\InstallLocation". [default] ENTER: "Cmdex::execute()" [app] Cmdex::execute(): Executing "'smartctl-nc.exe' --info --health --capabilities 'pd0'". [default] EXIT: "Cmdex::execute()" [default] ENTER: "Cmdex::stopped_cleanup()" [default] ENTER: "Cmdex::unset_stop_timeouts()" [default] EXIT: "Cmdex::unset_stop_timeouts()" [hz] Warning: exit: SMART status check returned "DISK FAILING" [hz] SMART status check returned "DISK OK" but some prefail Attributes are less than threshold. [default] EXIT: "Cmdex::stopped_cleanup()" [app] Skipping drive due to duplicate S/N: model: "HGST HTS545050A7E680", S/N: "TMA55C492D1TWL". [app] Could not open "\\.\PhysicalDrive1". [app] Could not open "\\.\PhysicalDrive2". [app] Could not open "\\.\PhysicalDrive3". [app] Stopping sequential scan. [app] {anonymous}::detect_drives_win32_areca(): Detecting drives behind Areca controller(s)... [app] No Areca software found. Install Areca CLI or set "system/win32_areca_scan_controllers" config key to 1 to force scanning. [default] ENTER: "Cmdex::stopped_cleanup()" [app] Found device: /dev/csmi0,0 (ata). [app] Found device: /dev/csmi0,2 (ata). [app] StorageDetector::detect(): Drive detection finished. [app] Retrieving basic information about the device... [app] Device information for /dev/csmi0,0 (type: "ata"): [app] Model: HGST HTS545050A7E680 [app] Detected type: unknown [app] SMART status: Enabled [app] Retrieving basic information about the device... [app] Device information for /dev/csmi0,2 (type: "ata"): [app] Model: [app] Detected type: unknown [app] SMART status: Unsupported [default] ENTER: "Cmdex::stopped_cleanup()" [app] StorageDevice::get_aodc_status(): AODC status: Disabled [app] Entering main loop. [app] GscMainWindowIconView::on_iconview_item_activated() [app] get_smartctl_binary(): Smartmontools installation not found in "HKLM\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall\smartmontools\InstallLocation". [default] ENTER: "Cmdex::execute()" [app] Cmdex::execute(): Executing "'smartctl-nc.exe' -d ata --health --info --get=all --capabilities --attributes --format=brief --log=xerror,50,error --log=xselftest,50,selftest --log=selective --log=directory --log=scttemp --log=scterc --log=devstat --log=sataphy '/dev/csmi0,0'". [default] EXIT: "Cmdex::execute()" [default] ENTER: "Cmdex::stopped_cleanup()" [default] ENTER: "Cmdex::unset_stop_timeouts()" [default] EXIT: "Cmdex::unset_stop_timeouts()" [hz] Warning: exit: SMART status check returned "DISK FAILING" [hz] SMART status check returned "DISK OK" but some prefail Attributes are less than threshold. [hz] The device error log contains records of errors. [default] EXIT: "Cmdex::stopped_cleanup()" [app] StorageDevice::get_aodc_status(): AODC status: Disabled [default] ENTER: "Cmdex::stopped_cleanup()" [app] GscInfoWindow::fill_ui_with_info(): Scan not requested. [app] GscMainWindow::on_action_activated(): Action activated: "action_executor_log" ------------------------- EXECUTION LOG ------------------------- ------------------------- EXECUTED COMMAND 1 ------------------------- ---------------Command--------------- 'smartctl-nc.exe' ---------------Parameters--------------- -V ---------------STDOUT--------------- smartctl 6.5 2016-05-07 r4318 [x86_64-w64-mingw32-win8.1] (sf-6.5-1) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org smartctl comes with ABSOLUTELY NO WARRANTY. This is free software, and you are welcome to redistribute it under the terms of the GNU General Public License; either version 2, or (at your option) any later version. See http://www.gnu.org for further details. smartmontools release 6.5 dated 2016-05-07 at 11:17:46 UTC smartmontools SVN rev 4318 dated 2016-05-07 at 11:18:20 smartmontools build host: x86_64-w64-mingw32 smartmontools build with: C++98, GCC 4.9.1 smartmontools configure arguments: 'build_alias=i686-pc-linux-gnu' 'host_alias=x86_64-w64-mingw32' 'LDFLAGS=-static' ---------------STDERR--------------- ---------------Error Message--------------- ------------------------- EXECUTED COMMAND 2 ------------------------- ---------------Command--------------- 'smartctl-nc.exe' ---------------Parameters--------------- --scan-open ---------------STDOUT--------------- /dev/sda -d ata # /dev/sda, ATA device /dev/csmi0,0 -d ata # /dev/csmi0,0, ATA device /dev/csmi0,2 -d ata # /dev/csmi0,2, ATA device ---------------STDERR--------------- ---------------Error Message--------------- ------------------------- EXECUTED COMMAND 3 ------------------------- ---------------Command--------------- 'smartctl-nc.exe' ---------------Parameters--------------- -d ata --info --health --capabilities '/dev/csmi0,0' ---------------STDOUT--------------- smartctl 6.5 2016-05-07 r4318 [x86_64-w64-mingw32-win8.1] (sf-6.5-1) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Hitachi/HGST Travelstar Z5K500 Device Model: HGST HTS545050A7E680 Serial Number: TMA55C492D1TWL LU WWN Device Id: 5 000cca 73be1aa3a Firmware Version: GG2OAF10 User Capacity: 500 107 862 016 bytes [500 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Form Factor: 2.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 6 SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sun Oct 15 22:39:07 2017 SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: FAILED! Drive failure expected in less than 24 hours. SAVE ALL DATA. Failed Attributes: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 5 Reallocated_Sector_Ct 0x0033 001 001 005 Pre-fail Always FAILING_NOW 0 General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 45) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 110) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. ---------------STDERR--------------- ---------------Error Message--------------- ------------------------- EXECUTED COMMAND 4 ------------------------- ---------------Command--------------- 'smartctl-nc.exe' ---------------Parameters--------------- -d ata --info --health --capabilities '/dev/csmi0,2' ---------------STDOUT--------------- smartctl 6.5 2016-05-07 r4318 [x86_64-w64-mingw32-win8.1] (sf-6.5-1) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org Read Device Identity failed: CSMI(25) failed with Error=170 A mandatory SMART command failed: exiting. To continue, add one or more '-T permissive' options. ---------------STDERR--------------- ---------------Error Message--------------- ------------------------- EXECUTED COMMAND 5 ------------------------- ---------------Command--------------- 'smartctl-nc.exe' ---------------Parameters--------------- --info --health --capabilities 'pd0' ---------------STDOUT--------------- smartctl 6.5 2016-05-07 r4318 [x86_64-w64-mingw32-win8.1] (sf-6.5-1) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Hitachi/HGST Travelstar Z5K500 Device Model: HGST HTS545050A7E680 Serial Number: TMA55C492D1TWL LU WWN Device Id: 5 000cca 73be1aa3a Firmware Version: GG2OAF10 User Capacity: 500 107 862 016 bytes [500 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Form Factor: 2.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 6 SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sun Oct 15 22:39:08 2017 SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: FAILED! Drive failure expected in less than 24 hours. SAVE ALL DATA. Failed Attributes: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 5 Reallocated_Sector_Ct 0x0033 001 001 005 Pre-fail Always FAILING_NOW 0 General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 45) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 110) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. ---------------STDERR--------------- ---------------Error Message--------------- ------------------------- EXECUTED COMMAND 6 ------------------------- ---------------Command--------------- 'smartctl-nc.exe' ---------------Parameters--------------- -d ata --health --info --get=all --capabilities --attributes --format=brief --log=xerror,50,error --log=xselftest,50,selftest --log=selective --log=directory --log=scttemp --log=scterc --log=devstat --log=sataphy '/dev/csmi0,0' ---------------STDOUT--------------- smartctl 6.5 2016-05-07 r4318 [x86_64-w64-mingw32-win8.1] (sf-6.5-1) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Hitachi/HGST Travelstar Z5K500 Device Model: HGST HTS545050A7E680 Serial Number: TMA55C492D1TWL LU WWN Device Id: 5 000cca 73be1aa3a Firmware Version: GG2OAF10 User Capacity: 500 107 862 016 bytes [500 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Form Factor: 2.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 6 SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sun Oct 15 22:39:16 2017 SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 1 (minimum power consumption with standby) Rd look-ahead is: Enabled Write cache is: Disabled ATA Security is: Disabled, frozen [SEC2] === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: FAILED! Drive failure expected in less than 24 hours. SAVE ALL DATA. See vendor-specific Attribute list for failed Attributes. General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 45) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 110) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0 2 Throughput_Performance P-S--- 100 100 040 - 0 3 Spin_Up_Time POS--- 253 253 033 - 0 4 Start_Stop_Count -O--C- 065 065 000 - 56098 5 Reallocated_Sector_Ct PO--CK 001 001 005 NOW 0 7 Seek_Error_Rate PO-R-- 100 100 067 - 0 8 Seek_Time_Performance P-S--- 100 100 040 - 0 9 Power_On_Hours -O--C- 076 076 000 - 10682 10 Spin_Retry_Count PO--C- 100 100 060 - 0 12 Power_Cycle_Count -O--CK 097 097 000 - 5588 191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0 192 Power-Off_Retract_Count -O--CK 100 100 000 - 93 193 Load_Cycle_Count -O--C- 058 058 000 - 421861 194 Temperature_Celsius -O---- 150 150 000 - 40 (Min/Max 11/45) 196 Reallocated_Event_Count -O--CK 094 094 000 - 343 197 Current_Pending_Sector -O---K 001 001 000 - 17752 198 Offline_Uncorrectable ---R-- 100 100 000 - 0 199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0 223 Load_Retry_Count -O-R-- 100 100 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 SATA NCQ Queued Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) Device Error Count: 959 (device log contains only the most recent 4 errors) CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 959 [2] occurred at disk power-on lifetime: 10682 hours (445 days + 2 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 08 00 00 01 b3 c5 00 01 00 Error: UNC at LBA = 0x01b3c500 = 28558592 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 08 00 60 00 00 17 50 35 98 40 00 08:11:04.259 READ FPDMA QUEUED 61 00 08 00 58 00 00 10 1f ae b0 40 00 08:11:03.767 WRITE FPDMA QUEUED 60 00 08 00 50 00 00 00 86 1d e8 40 00 08:11:03.275 READ FPDMA QUEUED 60 00 20 00 38 00 00 0d 5e cc 24 40 00 08:11:02.783 READ FPDMA QUEUED 60 00 28 00 10 00 00 02 04 de d8 40 00 08:11:02.291 READ FPDMA QUEUED Error 958 [1] occurred at disk power-on lifetime: 10682 hours (445 days + 2 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 08 00 00 01 b3 c5 00 01 00 Error: UNC at LBA = 0x01b3c500 = 28558592 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 08 00 38 00 00 0f f2 ad d0 40 00 08:11:00.323 READ FPDMA QUEUED 61 00 48 00 30 00 00 33 5d dc f8 40 00 08:10:59.831 WRITE FPDMA QUEUED 61 00 08 00 28 00 00 00 8a ed 58 40 00 08:10:59.339 WRITE FPDMA QUEUED 61 00 08 00 20 00 00 03 51 6c e0 40 00 08:10:58.847 WRITE FPDMA QUEUED 60 00 40 00 18 00 00 03 c8 16 d2 40 00 08:10:58.356 READ FPDMA QUEUED Error 957 [0] occurred at disk power-on lifetime: 10682 hours (445 days + 2 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 08 00 00 01 b3 c5 00 01 00 Error: UNC at LBA = 0x01b3c500 = 28558592 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 01 00 00 00 00 00 00 89 c0 00 40 00 07:39:08.428 READ FPDMA QUEUED 60 00 08 00 08 00 00 31 3b 82 a8 40 00 07:39:08.407 READ FPDMA QUEUED 60 01 00 00 00 00 00 00 8a fd 00 40 00 07:39:08.403 READ FPDMA QUEUED 60 01 00 00 00 00 00 00 89 a1 00 40 00 07:39:08.395 READ FPDMA QUEUED 60 00 08 00 48 00 00 01 b3 c5 00 40 00 07:39:08.364 READ FPDMA QUEUED Error 956 [3] occurred at disk power-on lifetime: 10682 hours (445 days + 2 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 08 00 00 01 b3 c5 00 01 00 Error: UNC at LBA = 0x01b3c500 = 28558592 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 08 00 40 00 00 31 3f 1e 70 40 00 07:39:08.089 READ FPDMA QUEUED 60 00 40 00 38 00 00 00 6c a9 42 40 00 07:39:07.364 READ FPDMA QUEUED 60 00 08 00 30 00 00 00 95 52 91 40 00 07:39:06.873 READ FPDMA QUEUED 61 00 20 00 28 00 00 12 8a cc 60 40 00 07:39:06.381 WRITE FPDMA QUEUED 60 00 40 00 20 00 00 00 46 21 72 40 00 07:39:05.888 READ FPDMA QUEUED SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) SCT Support Level: 1 Device State: Active (0) Current Temperature: 40 Celsius Power Cycle Min/Max Temperature: 22/40 Celsius Lifetime Min/Max Temperature: 11/45 Celsius Lifetime Average Temperature: 32 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -40/65 Celsius Temperature History Size (Index): 128 (69) Index Estimated Time Temperature Celsius 70 2017-10-15 20:32 32 ************* ... ..( 50 skipped). .. ************* 121 2017-10-15 21:23 32 ************* 122 2017-10-15 21:24 33 ************** 123 2017-10-15 21:25 33 ************** 124 2017-10-15 21:26 32 ************* ... ..( 5 skipped). .. ************* 2 2017-10-15 21:32 32 ************* 3 2017-10-15 21:33 33 ************** ... ..( 2 skipped). .. ************** 6 2017-10-15 21:36 33 ************** 7 2017-10-15 21:37 34 *************** 8 2017-10-15 21:38 35 **************** ... ..( 2 skipped). .. **************** 11 2017-10-15 21:41 35 **************** 12 2017-10-15 21:42 36 ***************** ... ..( 11 skipped). .. ***************** 24 2017-10-15 21:54 36 ***************** 25 2017-10-15 21:55 37 ****************** ... ..( 4 skipped). .. ****************** 30 2017-10-15 22:00 37 ****************** 31 2017-10-15 22:01 38 ******************* ... ..( 3 skipped). .. ******************* 35 2017-10-15 22:05 38 ******************* 36 2017-10-15 22:06 39 ******************** ... ..( 8 skipped). .. ******************** 45 2017-10-15 22:15 39 ******************** 46 2017-10-15 22:16 40 ********************* ... ..( 22 skipped). .. ********************* 69 2017-10-15 22:39 40 ********************* SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP/SMART Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0009 2 65535+ Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 3 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS ---------------STDERR--------------- ---------------Error Message---------------